Skip to end of metadata
Go to start of metadata

Beet reserves the right to modify this information at any time without notification.

PLC Impact of ePVS Driver

PLC Type
(Model)
Core Driver Only

Driver w/ 3 Assets, 60 Groups,
and 100 Operations
MemoryScan TimeMemoryScan Time
Siemens 300-400 via Built-In port
(CPU 319F-3 PN/DP)
29.4KB - Load Memory3ms 42.9KB - Load Memory3-4ms
Siemens 300-400 via CP Module
(CPU 319F-3 PN/DP)
28.5KB - Load Memory3ms42KB - Load Memory3-4ms
Siemens 1200-1500
(CPU 1515F-2 PN)
206.6KB - Load Memory18ms491.6KB - Load Memory18-19ms
Mitsubishi Q
(QCPU [Q Mode])
Program: 36KB / 9216 Steps (Depends on PLC Model)
Data: 3560 K Points
4.5msProgram: 44KB / 11264 Steps (Depends on PLC Model)
Data: 3560 K Points
4.8ms
Rockwell CLx
(1756-L62)
124KB2-3ms134KB3-5ms
PLC58K Words5-10ms10K Words5-10ms
SLC5004500 Words5-10ms5500 Words5-10ms

Scan Time

Scan time impact will vary from PLC model and number of state changes per scan.


GCP Cloud (pub-sub) Internet Network Up-link Utilization

This is streaming data based on actual historical production of a body shop, then extrapolated. 

Network usage is based on Cycle Times and data Rate of Change.  Data is only transmitted while machines are in operation.

Please use this as a estimate only, actual results will vary.


Actual Gen 2 Network Utilization Monitoring

772 Smart Tags

PLC Message In-Bound (6 PLCs)

Cloud Up-Link

2943 Smart Tags

PLC Message In-Bound (23 PLCs)

Cloud Up-Link

3320 Smart Tags

PLC Message In-Bound (19 PLCs)

Cloud Up-Link